Additional information
You can find additional information on the topic of "Connecting the CPU" and on the topic
"Accessories/spare parts" in the system manual for Redundant System S7‑1500R/H
(https://support.industry.siemens.com/cs/ww/en/view/109754833).
Assignment of the MAC addresses
For each CPU, CPU1517H‑3PN has:
•
One PROFINET interface with two ports
•
One PROFINET interface with one port
•
Two H‑Sync interfaces with one port each
Each of the interfaces has a MAC address. Each port also has a separate MAC address. There
are a total of eighteen MAC addresses for the two CPUs of the CPU1517H‑3PN.
The MAC addresses of the ports are needed for the LLDP protocol, for example for the
neighborhood discovery function.
The number range of the MAC addresses is sequential. The first and last MAC addresses are
printed on the rating plate on the right side of each CPU1517H‑3PN.
The table below shows how the MAC addresses are assigned.
Table 4-2Distribution of the MAC addresses of a CPU
Assignment Labeling
MAC address 1 PROFINET interface X1
(visible in STEP7 when devices are accessible)
• Front printed
• Right-side printed
(start of number range)
MAC address 2 Port X1P1R (required for LLDP, for example) ---
MAC address 3 Port X1P2R (required for LLDP, for example) ---
MAC address 4 PROFINET interface X2
(visible in STEP7 when devices are accessible)
• Front printed
MAC address 5 Port X2P1 (required for LLDP, for example) ---
MAC address 6 H-Sync interface X3 • Front printed
MAC address 7 Port X3P1 ---
MAC address 8 H-Sync interface X4 • Front printed
MAC address 9 PortX4P1 • Right-side printed
(end of number range)