4 Configuration and Project Engineering 
4.1 Creating the project configuration 
 
SINAMICS G120 as a Speed Axis on the S7-1500 
V1.0a, Entry ID: 78788716 
 
Copyright  Siemens AG 2013 All rights reserved 
No.  Action  Picture 
14.    In 
 >Cyclic data exchange 
 >Actual value, 
make sure that “Standard 
telegram 1” is selected. 
or 
Parameterizing the SINAMICS G120 
15.    Perform “basic 
commissioning of the drive on 
a SIMATIC motion control 
axis” with the aid of the 
wizard. 
To do so, select  
 >Drive_1 [G120…] 
 >Parameter  
in the Project tree  
…and click on the “Drive on 
SIMATIC motion control axis” 
wizard.