Ethernet Gateway for SIMATIC MPI/PROFIBUS Driver
GP-Pro EX Device/PLC Connection Manual
15
5 Supported Device Addresses
The following table shows the range of supported device addresses. Please note that the actual supported range of
the devices varies depending on the External Device to be used. Please check the actual range in the manual of
your External Device.
5.1 S7-200 Series
: This address can be specified as system data area.
Device
Bit Address Word Address
32
bits
Remarks
English German English German
Variables - VW00000 - VW05118
Input
I00000.0 -
I00015.7
E00000.0 -
E00015.7
IW00000 -
IW00014
EW00000 -
EW00014
*1
*1 You cannot write to IW0 to IW2 depending on the CPU type. These addresses are reserved for onboard I/O.
Please refer to the manual of your External Device for checking.
Output
Q00000.0 -
Q00015.7
A00000.0 -
A00015.7
QW00000 -
QW00014
AW00000 -
AW00014
*2
*2 You can write in the QW and Q devices only when the External Device is in RUN mode. When the External
Device moves to the STOP mode, the output will be reset.
Internal Marker M00000.0 - M00031.7 MW00000 - MW00030
Timer - T00000 - T00255
*3
*3 Write disable
Counter -
C00000 -
C00255
Z00000 -
Z00255
*3
• Please refer to the GP-Pro EX Reference Manual for system data area.
Cf. GP-Pro EX Reference Manual "LS Area (Direct Access Method Area)"
• Please refer to the precautions on manual notation for icons in the table.
"Manual Symbols and Terminology"