Ethernet Gateway for SIMATIC MPI/PROFIBUS Driver
GP-Pro EX Device/PLC Connection Manual
9
4 Setup Items
Set up the Display's communication settings in GP Pro-EX or in the Display's off-line mode.
The setting of each parameter must match that of the External Device.
"3 Communication Settings" (page 7)
4.1 GP-Pro EX Setup Items
Communication Settings
To display the setup screen, from the [Project] menu, point to [System Settings] and select [Device/PLC].
Setup Items Setup Description
Port No.
Enter a port number of the Display, using 1024 to 65535. Check into [Auto], and a port
number is set automatically.
Timeout
Use an integer from 1 to 127 to enter the time (s) for which Display waits for the response
from External Device.
Retry
In case of no response from the External Device, use an integer from 0 to 255 to enter how
many times the Display retransmits the command.
Wait To Send
Use an integer from 0 to 255 to enter standby time (ms) for the Display from receiving
packets to transmitting next commands.