Errors and diagnostics
11.5 Operator error
Counter module FM 450-1
Manual, 02/2014, A5E03648739-02
111
Diagnostic data record DS1
Diagnostic data record DS 1 consists of 12 bytes. The first 4 bytes are identical to diagnostic
data record DS0. The following table shows the assignment of the remaining bytes. All bits
not listed have no meaning and are zero. This data record is entered into DB 1 from DW54
with the FC DIAG_INF.
Table 11- 2 Assignment of the bits of bytes 4 to 12 of the diagnostic data record DS1
4
Diagnostic information length
7 0 Channel fault vector Bit 0 = 1: Fault on channel 1
Bit 1 = 1: Fault on channel 2
8
Signal A - faulty channel 1
Signal B - faulty channel 1
Signal N faulty channel 1
5.2V encoder supply faulty channel 1
10
Signal A - faulty channel 2
Signal B - faulty channel 2
Signal N faulty channel 2
5.2V encoder supply faulty channel 2
11 Reserved
How does the diagnostic text appear in the diagnostic buffer?
If you want to enter the diagnostic message in the diagnostic buffer, you must call the
SFC 52 (Enter user-specific message in the diagnostic buffer" in the user program. The
event number of the diagnostic message in each case is specified in the input parameter
EVENTN. The interrupt is entered in the diagnostic buffer with x=1 as incoming and x=0 as
outgoing. The diagnostic buffer contains the relevant diagnostic text in the "Meaning" column
as well as the time of the entry.
The diagnostic interrupt is disabled in the default setting.