AL S
08.95
AL S/1-1
 Siemens AG 1997 All Rights reserved    6SN1197–0AA20 
 SIMODRIVE 611  (PJ)
Electrical data
1.1 Definitions
S3 (100 K)–25 %
1
2
3
4
Max. mechanical torque
M
M
0
 
(100
 
K)
10 min
10 min
10 min
S1 (100 K)
n  [RPM]
 
Thermal limiting characteristics for
 Continuous operation
S1 (100 K) and S1 (60 K)
,
 Intermittent operation
S3–60 % (100 K), S3–40 % (100 K)
S3–25 %  (100 K)
for a 10 min duty cycle.
Speed limits n
max
CF H K
S1 (60 K)
1000 3000 4000 5000 60002000
7000
S3 (100 K)–40 %
S3 (100 K)–60 %
>Voltage limiting characteristics
M
limit
M
limit
M
limit
M
limit
(Examples for winding designs)
Fig. 1-1 Normalized speed–torque diagram
Characteristics
General information on AC servomotors
1  Electrical data
1