02.98
1-27
Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
P
n
, P
s6
, P
max
Data is valid for the total, permitted voltage range of the I/R
modules.
P
n
Continuous output of the NE module.
P
s6
Output for max. 4 min for an S6 duty cycle.
P
max
Peak output.
Refer to the following load duty diagrams for the duty cycle diagrams.
Pv
total
Total module power loss;
Pv
pipe
Power loss dissipated with pipe cooling;
Pv
ext
Power loss dissipated with external cooling;
Pv
int
Power loss which cannot be dissipated through pipe– or ex-
ternal cooling.
This power loss remains in the cabinet.
Table 3-4 Supply voltage and frequency
S1, S4 = OFF
Vn = 3–ph. 400V AC
S1 = ON
Vn = 3–ph. 415V AC
S4 = ON
Vn = 3–ph. 480V AC
NE modules up to P
n
v55kW
3–ph. 360...440V AC
3–ph. 300...360V AC
1)
45...65Hz
3–ph. 373...457V AC
3–ph. 312...373V AC
1)
45...65Hz
3–ph. 432...509V AC
3–ph. 408...432V AC
1)
55...65Hz
I/R modules Pn = 80/120kW
power connection: U1, V1, W1
3–ph. 360...440V AC
3–ph. 300...360V AC
1)
45...65Hz
3–ph. 373...457V AC
3–ph. 312...373V AC
1)
45...65Hz
3–ph. 432...509V AC
3–ph. 408...432V AC
1)
55...65Hz
Coil connection: L1, L2
3–ph. 360...457V AC / 45...53Hz
3–ph. 400...510V AC / 57...65Hz
All I/R modules and the UE 28 kW are force ventilated.
The UE modules 5kW, 10kW, the monitoring module as well as the pulsed resi-
stor module, are self–ventilated.
Before powering–up for the first time, the cabinet wiring, motor/encoder feeder
cables and the DC link connections must be checked to ensure that they do not
have a ground fault.
1)
The drive power supply can be operated in the range from 3–ph. 323 to 3–ph. 509 V AC. However, for I/R modules,
operation of the power supply up to 3–ph. 280 V AC is only valid as long as the I/R module actively controls the
DC link voltage 600 V or 625 V and there is a three–conductor connection (as set in the factory).
De–rating to 0.7P
n
. Power supply rating must, under the conditions, also be reduced to 70%.
A
P
+E
P
0.7 x (17+8) or for UE 5 kW 0.7 x (7+3.5)
2)
In the infeed direction, the DC link voltage is uncontrolled, therefore a 600 V DC link voltage
will not be achieved. Observe the restrictions regarding the acceleration time and stall torque of the motors.
Definition of
powers
Supply
voltage and
frequency
Cooling type
No ground–fault
3.2.1 Technical data, supply infeed modules

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMODRIVE 611A and is the answer not in the manual?

Siemens SIMODRIVE 611A Specifications

General IconGeneral
BrandSiemens
ModelSIMODRIVE 611A
CategoryInverter
LanguageEnglish

Related product manuals