EasyManua.ls Logo

Siemens SIMODRIVE 611A - Page 293

Siemens SIMODRIVE 611A
329 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1FT5
08.95
1FT5/3-43
Siemens AG 1997 All Rights reserved 6SN1197–0AA20
SIMODRIVE 611 (PJ)
Cantilever force F
Q
at distance x from the shaft shoulder for a nominal bearing
lifetime of 20,000 hours.
1000
3000
5000
F
Q
7000
9000
2000
4000
6000
8000
St60–2
n=60 RPM
n=120 RPM
n=300 RPM
n=600 RPM
0
x[mm]
0
10000
12000
14000
11000
N
n=1000 RPM
704020 3010 6050 80
n=1500 RPM
n=2000 RPM
n=3000 RPM
n=4000 RPM
n=6000 RPM
Permissible axial force as a function of the cantilever force.
4000
5000
F
Q
AS
2000
4000
0
0
F
A
AS
n=60 RPM
1000
3000
50001000
3000 7000 110009000 N 14000
N
7000
9000
6000
8000
11000
6000
3000
2000
1500
Cantilever force
1FT5132 to
1FT5136
Axial force
1FT5132 to
1FT5136
1FT5 AC servomotors
3.2 Cantilever/axial force dia
g
rams