Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
Table 3-9
T.–
No.
Des. Function
Type
1)
Typ. voltage/limit values
Max. cross–
section
111
213
X161
X161
Signaling contact
Line contactor
I
NC
1–ph. 250 V AC/50 V DC/2 A
17 V DC/3 mA min
1.5 mm
2
1.5 mm
2
9
2)4)
112
48
NS1
NS2
15
X141B
X141B
X141B
X141B
X141B
X141B
FR+
Setting–up no–/standard mode
Contactor control
M
Coil contact for line–,
pre–charging contactor
O
I
I
O
I
O
+24 V
+13 V...30 V/R
E
= 1.5 kΩ
+13 V...30 V/R
E
= 1.5 kΩ
+24 V
0/+24 V
0 V
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1) I = input; O = output; NC = NC contact; NO = NO contact
2) Terminal 19 is the reference terminal (this is connected in the module with 10 kW to general reference ground
X131)
It is not permissible to connect terminal 15 with PE or with terminal 19, further, no external voltage sources
may be connected to terminal X131.
3) The grounding bar is used to ground the DC link M rail through 100 kΩ (should be preferably inserted).
4) Max. current load of terminal 9 – terminal 191 A
Caution: Terminals 7, 45, 44 and 10 are not available for UE 5/10 kW.
3.3.2 Interface overview UE module 5/10 kW