3
02.98
1-46
 Siemens AG 1998 All Rights reserved    6SN1197–0AA00 02.98 Edition
SIMODRIVE 611  (PJ)
Table 3-12 
Assignment of the commutating reactor for only square–wave current operation
I/R module
80/104 kW
I/R module
120/156
 kW
Type 80 kW commutating reactor 120 kW commutating reactor
Order No.
6SN1111–0AA00–
–0EA0  (only for square–wave current) –0FA0         (only for square–wave current)
L
phase
0.235 mH 0.215 mH
I
n
150 A 225 A
Volt. drop/phase 11.1 V 15.2 V
Pv 450 W 590 W
Connection cross–section 9 mm drilling 9 mm drilling
Weight 50 kg 61 kg
Mounting position Any Any
Terminal assignment
Connections at the top: output
1U2, 1V2, 1W2
Connections at the bottom: Input
1U1, 1V1, 1W1
Drilling template
Dimensions in mm
Surface,
Top view
143
224
max.230
max.330
18
10
Height 290
Surface,
Top view
138
264
max.225
max.380
18
10
Height 340
Permissible operating mode as a function of the commutating reactor used or
the filter module used.
Table 3-13 Assignment of the commutating reactor/filter module to the operating mode
I/R
16 kW
I/R
36 kW
I/R
55 kW
I/R
80 kW
I/R
120 kW
Commutating reactor
(acc. to Table 3-11)
Squ.–wave/si-
nus.
 Ɩ    
Squ.–wave/si-
nus.
 Ɩ  
Squ.–wave/si-
nus.
 Ɩ  
Squ.–wave/si-
nus.
 Ɩ  
Squ.–wave/si-
nus.
 Ɩ  
Commutating reactor
(acc. to Table 3–8)
Squ.–wave Ɩ Squ.–wave Ɩ
Commutating reactor
(6SC611 system)
Squ.–wave Ɩ Squ.–wave Ɩ Squ.–wave Ɩ Squ.–wave Ɩ Squ.–wave Ɩ
Filter module
(acc. to Table 3-16)
Squ.–wave Ɩ Squ.–wave Ɩ Squ.–wave Ɩ Squ.–wave Ɩ Squ.–wave Ɩ
Note
I/R in sinusoidal operation may not be used with other reactors.
3.4.2  Assignment of the commutating reactors to the NE modules