SIMODRIVE 611 (PJ)
Table 4-4 Currents for an inverter clock frequency f
0
=4.0 KHz (de–rating)
Power
module
8 A
*
15 A
*
25 A
*
50 A
*
80 A
*
108 A
*
160 A
*
200 A
*
300 A
*
400 A
*
I
rated
A2.8 A4.6 A7.4 A22.0 A28.0 A42.0 A55.0 A79.0 A110 A183
0.7
I
rated
A2.0 A3.2 A5.2 A15.4 A19.6 A29.4 A38.5 A55.3 A77 A128
I S6-60% A2.8 A4.6 A7.4 A23.8 A31.7 A46.7 A64.2 A92.9 A124 A206
I S6-40% A2.8 A4.6 A9.3 A29.0 A37.0 A56.0 A73.0 A102 A138 A229
I S6-30% A2.8 A4.7 A10.0 A29.0 A38.8 A57.8 A79.7 A104 A140 A231
I S6-25% A2.8 A4.9 A10.6 A29.0 A40.7 A59.9 A82.2 A107 A142 A232
I S6-20% A2.8 A5.2 A11.4 A29.0 A42.1 A62.4 A84.7 A110 A146 A233
I S6-10% A2.8 A6.0 A13.8 A29.0 A44.8 A66.6 A89.8 A113 A159 A234
I
max
A2.8 A7.3 A14.8 A29.0 A47.0 A70.0 A94.0 A117 A177 A236
The 0.7I
rated
current is kept constant.
* Currents are only valid for induction motor applications digital, int. and ext. cooling.
Observe de–ratings for additional possible clock frequencies and installation altitude.
Technical data of the supplementary components
Refer to p.1-34 for the supplementary components required
4.1 Technical data