Loading...
Ensure that condensate can drain away
In the bearing shields on the DE and NDE, water drainage holes are situated below or opposite
the regreasing devices. They are sealed with screw plugs. Depending on the type of
installation, the water drainage holes are located at the bottom.
1. Regularly remove the screw plugs to allow the condensate to drain away.
2. Replace them when you have finished.
Figure 5-2 Schematic diagram of the water drain holes
NOTICE
The degree of protection is reduced
Nominally the degree of protection of the machine is reduced to IP44 when the screw plug is
removed.
5.2.9 Roughly aligning the machine
Requirement
The transmission element such as a coupling half has already been pulled on.
Roughly aligning the machine
For horizontal positioning, push the motor sideways across the foundation. When doing so,
ensure that the axial position is maintained.
Assembly
5.2 Lift the machine to where it will be installed, and position it