Mounting
4.6 Vibration response
1FK7 G2 synchronous motors
64 Operating Instructions, 05/2021, A5E50907562B AA
1
End shield DE radial
4
End shield NDE radial
2
End shield DE radial
5
End shield NDE axial
3
End shield DE axial
6
End shield NDE radial
Figure 4-6 Measuring points for vibration values
The vibration acceleration is evaluated in the frequency band from 10 to 2000 Hz. Whereby,
the maximum peak value in the time range is considered.
To evaluate the vibration velocity, the measuring equipment must fulfill the requirements of
ISO 2954.