Description of the motors
2.3 Derating factors
1FK7 G2 synchronous motors
Operating Instructions, 05/2021, A5E50907562B AA
27
2.3 Derating factors
Under conditions other than those specified above (ambient temperature > 40° C or
installation altitude > 1000 m above sea level), the permissible torques/powers are shown in
the following table.
Ambient temperatures and installation altitudes are rounded off to 5° C or 500 m
respectively.
Table 2- 4 Power de-rating depending on the installation altitude and the ambient temperature
Installation altitude
above sea level in m
Ambient temperature in °C
Factors xD refer to static torque M0.
Determine the reduced torque using the following formula:
red
N
0
0
xD))
Mred / Nm = reduced torque at rated speed
MN / Nm = rated torque S1 (100K)
M0 / Nm = static torque (100K)
You shift the S1 characteristic curve in parallel.
At installation altitudes of 2000 m above sea level or higher, the voltage stress on the motors
must be reduced accordingly based on the "Factors for reducing the maximum DC-link
voltage" table (reciprocal values from EN 60664-1 Table A. 2).
Table 2- 5 Factors for reducing the maximum DC-link voltage
Installation altitude up to [m] above mean sea
Factor
As the DC-link voltage is reduced, the converter output voltage also decreases. This reduces
the operating range in the M-n diagram.
The M-n diagrams are contained in the associated Configuration Manual.
Operation in a vacuum is not permissible because of the low dielectric strength and poor heat
dissipation.