5.4 System integration
1FK7 G2 synchronous motors
96 Operating Instructions, 05/2021, A5E50907562B AA
Connecting procedure
1. Remove the 4 screws (6) of the fan cover (2) and the lifting eyes (7).
4
Signal connector on the encoder
8
3 cable glands on the fan cover
2. Remove the fan cover (2).
3. Align the signal connector (4), at 90° to the motor axis left or right.
4. Connect the signal connector (4).
5. Close the superfluous cable glands (8) with the sealing caps (5).
6. Mount the fan cover (2) with the screws (6) (tightening torque 9 Nm). Secure all screw
connections against unwanted loosening (e.g. with Loctite 243). Reattach any lifting eyes.