4.4 Encoder
4.4.1 Encoder with DRIVE-CLiQ
Description
Motors with DRIVE-CLiQ interface are designed to operate with the SINAMICS converter system.
The signal is digitally transferred to the converter.
The motors have an electronic rating plate that simplies commissioning and diagnostics.
The motor and encoder are automatically identied and all motor parameters are
automatically set.
You will nd further information in the relevant SINAMICS manual.
NOTICE
Damage to electrostatic sensitive devices
The contacts of the DRIVE-CLiQ interface have direct contact with components that can be
destroyed by electrostatic discharge (ESDS).
• Avoid touching the terminals directly with hands or tools. They could be charged
electrostatically and damage components.
The encoders are suitable for the Extended Safety functions.
Encoders that are available for the 1FT2
The 1FT2 is available with the following encoders:
Encoder designa‐
tion
AS22DQC AM22DQC AS26DQC AM26DQC
Description Absolute encoder 22-
bit singleturn
Absolute encoder 22-
bit+12-bit multiturn
Absolute en‐
coder 26-bit
singleturn
Absolute en‐
coder 26-
bit + 12-bit mul‐
titurn
Identier at the 14th
digit of the article
number
S M B C
Operating voltage 24V 24V 24V 24V
Maximum current
consumption
70mA 70mA 70mA 70mA
Resolution 4,194,304=22 bit 4,194,304=22 bit 67,108,864=2
6bit
67,108,864=2
6bit
Mounting and options
4.4Encoder
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
44 Operating Instructions, 12/2023, A5E50610821B AF