EasyManua.ls Logo

Siemens SIMOTICS S-1FT2 - Vibration Response and Severity

Siemens SIMOTICS S-1FT2
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.6 Vibration response
Vibration severity grade
Motors with keyway are balanced by the manufacturer using a half-key.
The vibration response of the system at the location of use is in󹪞uenced by output elements,
any built-on parts, the alignment, the installation, and external vibrations. This can change
the vibration values of the motor.
The motors conform to vibration severity grade A according to EN60034-14 (IEC60034-14).
The speci󹪝ed values refer only to the motor. The installation-dependent system vibration
behavior can increase these values at the motor.
The vibration severity grade is maintained up to the rated speed (n
N
)
W
NNT
F꫻QFSN
(SBEF"






OSNJO
Figure6-3 Vibration severity levels
Vibration response
Comply with the vibration values in the following table to ensure perfect functioning of the
motor and a long service life.
Motor Vibration velocity
V
rms
acc. to ISO 10816-1: 1997-08
(historical)
Vibration acceleration
a
peak
axial
Vibration acceleration
a
peak
radial
Naturally
cooled
max. 4.5mm/s 50m/s
2
50m/s
2
Force ventila‐
ted
max. 4.5mm/s 25m/s
2
25m/s
2
The measuring equipment must ful󹪝ll the requirements of ISO2954 to evaluate the vibration
velocity
Select the measuring points based on ISO10816-1: 1997-08 (historical), Section 3.2.
The vibration acceleration is evaluated in the frequency range from 10Hz…2000Hz. The
maximum peak in the measurement time range is taken into consideration.
Mounting
6.6Vibration response
SIMOTICS S-1FT2 synchronous motors for SINAMICS S120
Operating Instructions, 12/2023, A5E50610821B AF 75