Evaluation of the safety function according to EN 62061
11.5 Result when using two power contactors
Application document for functional safety STO, SS1 (ISO 13849-1)
Compact User Manual, 09/2016, A5E34871844AM
69
11.5
Result when using two power contactors
SILCL
PFH
D
DETECT
3
8.33 E-10
EVALUATE 3 5.42 E-09
RESPOND
3
3.24 E-10
Result
Reason
SILCL
SIL claim limit
3 The SILCL of all tasks of the supplementary safety function
is at least 3.
PFH
D
Average probability of a dangerous
failure per hour
2.57 E-08