EasyManua.ls Logo

Siemens SINAMICS G120 - Frequently Required Parameters

Siemens SINAMICS G120
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
4.4 Frequently required parameters
CU240B-2 and CU240E-2 Control Units
28 Compact Operating Instructions, 04/2015, A5E35792002B AA
Status word 1 (ZSW1), PZD send word 1 (word: p2051[0], bits: p2080[0] … p2080[15])
Bit
Meaning
Comments
0
1 = Ready to start
Power supply switched on; electronics initialized; pulses locked.
1 1 = Ready Motor is switched on (ON/OFF1 = 1), no fault is active. With the command "Enable
operation" (STW1.3), the inverter switches on the motor.
2
1 = Operation enabled
Motor follows setpoint. See control word 1, bit 3.
3 1 = Fault active The inverter has a fault. Acknowledge fault using STW1.7.
4
1 = OFF2 inactive
Coast down to standstill is not active.
5
1 = OFF3 inactive
Quick stop is not active.
6
1 = Closing lockout active
It is only possible to switch on the motor after an OFF1 followed by ON.
7
1 = Alarm active
Motor remains switched on; no acknowledgement is necessary.
8 1 = Speed deviation within the
tolerance range
Setpoint / actual value deviation within the tolerance range.
9
1 = Master control requested
The automation system is requested to accept the inverter control.
10 1 = Comparison speed reached
or exceeded
Speed is greater than or equal to the corresponding maximum speed.
11
1 = torque limit reached
Comparison value for current or torque has been reached or exceeded.
12
1 = Holding brake open
Signal to open and close a motor holding brake.
13 0 = Alarm, motor overtempera-
ture
--
14
1 = Motor rotates clockwise
Internal inverter actual value > 0
0 = Motor rotates counter-
clockwise
Internal inverter actual value < 0
15 0 = Alarm, inverter thermal
overload
4.4
Frequently required parameters
Parameter
Explanation
p0015
Macro drive unit
Set defaults for inputs and outputs via a macro.
r0018
Control Unit firmware version
p0096
Application class
0: Expert
1: Standard Drive Control
2: Dynamic Drive Control
p0100
IEC/NEMA mot stds
0: Europe 50 [Hz]
1: NEMA motor (60 Hz, US units)
2: NEMA motor (60 Hz, SI units)
p0304
Rated motor voltage [V]
p0305
Rated motor current [A]
p0307
Rated motor power [kW] or [hp]
p0310
Rated motor frequency [Hz]
p0311
Rated motor speed [rpm]

Other manuals for Siemens SINAMICS G120