Installing
3.2 Connecting
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
25
3.2.5
Default settings of the terminals
Available settings of the terminals
Default setting 1: Two fixed speeds
Selected with
STARTER: Conveyor technology
with 2 fixed frequencies
BOP-2: coN 2 SP
Default setting 2: Two fixed speeds
with safety function
Selected with
STARTER: Conveyor systems with
Basic Safety
BOP-2: coN SAFE
Default setting 3: Four fixed speeds
Selected with
STARTER: Conveyor technology
with 4 fixed frequencies
BOP-2: coN 4 SP
Fieldbus interface is not active.
DI 4 and DI 5 = high: The inverter adds
both fixed speeds.
Fieldbus interface is not active.
DI 0 and DI 1 = high: The inverter adds
both fixed speeds.
Fieldbus interface is not active.
Multiple DIs = high: The inverter adds
the corresponding fixed speeds.
Default setting 4: PROFIBUS or
PROFINET
Selected with
STARTER: Conveyor systems with
fieldbus
BOP2: coN Fb
Default setting 5: PROFIBUS or
PROFINET with safety function
Selected with
STARTER: Conveyor systems with
fieldbus and Basic Safety
BOP-2: coN Fb S
PROFIdrive telegram 352
PROFIdrive telegram 352

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating