Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
45
09 Activate motor temperature model 2
Thermal resistor adaptation reduction factor
t motor model fault threshold [°C]
Motor ambient temperature [°C]
Q flux, flux gradient saturated [mH]
CU number of inputs and outputs
CO/BO: CU digital inputs, status
DI 11 (terminals 3, 4) AI 0
CO/BO: CU digital inputs, status inverted
BI: CU signal source for terminal DO 0
NO: Terminal 19 / NC: Terminal 18
BI: CU signal source for terminal DO 1
CU, digital outputs status
CU, invert digital outputs
BO: CU analog inputs status word
r0752 CO: CU analog inputs input voltage/current actual
r0755 CO: CU analog inputs actual value in percent, AI0
(terminals 3/4) [100 ≙ 100%]
CU analog input type (terminals 3, 4)
Unipolar voltage input (0 V ... +10 V)
1 Unipolar voltage input monitored
Unipolar current input (0 mA … +20 mA)
3 Unipolar current input monitored (+4 mA …
Bipolar voltage input (-10 V...+10 V)
CU analog input characteristic value x1
CU analog input characteristic value y1 [%]
CU analog input characteristic value x2
CU analog input characteristic value y2 [%]
p0761 CU analog input wire break monitoring response
CU analog inputs deadband [V]
p0771 CI: CU analog output signal source, AO 0
(terminals 12, 13) [100 ≙ 100%]
CU analog output, output value currently referred
r0774 CU analog output, output voltage/current actual
p0775 CU analog output activate absolute value
Current output (0 mA ... +20 mA)
Voltage output (0 V... +10 V)
Current output (+4 mA ... +20 mA)
CU analog output characteristic value x1 [%]
CU analog output characteristic value y1 [V]
CU analog output characteristic value x2 [%]
CU analog output characteristic value y2 [V]
p0782 BI: CU analog output invert signal source, AO 0
(terminals 12,13)
r0785
BO: CU analog outputs status word
CU digital inputs, simulation mode
CU digital inputs, simulation mode setpoint