Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
49
1 Buffer V
DC
until undervoltage, n<p1257 →
F07405, t>p1255 → F07406
p1257
V
DC_min
controller speed threshold [rpm]
p1271
Flying restart maximum frequency for the inhibited
direction [Hz]
p1280
V
DC
controller or V
DC
monitoring configuration (V/f)
0
Inhibit V
DC
controller
1
Enable V
DC_max
controller
r1282 V
DC_max
controller switch-in level (V/f) [100 % ≙
p2001]
p1283
V
DC_max
controller dynamic factor (V/f) [%]
p1284
V
DC_max
controller time threshold (U/f) [s]
p1300
Open-loop/closed-loop control operating mode
0
V/f control with linear characteristic
1
V/f control with linear characteristic and FCC
2
V/f control with parabolic characteristic
3
V/f control with parameterizable characteristic
4
V/f control with linear characteristic and ECO
5 V/f control for drive requiring a precise
frequency (e.g. textiles)
6 V/f control for drive requiring a precise
frequency and FCC
7 V/f control for parabolic characteristic and
ECO
19
V/f control with independent voltage setpoint
20
Speed control (without encoder)
p1302
V/f control configuration
.03 Motor holding brake with constant stop
frequency
p1310
Voltage boost permanent [100 % p0305]
p1311
Voltage boost when accelerating [%]
p1312
Voltage boost when starting [%]
r1315
Voltage boost, total [100 % p2001]
p1320 V/f control programmable characteristic frequency
1 [Hz]
p1321 V/f control programmable characteristic voltage 1
[V]
p1322
Characteristic frequency 2 [Hz]
p1323
Characteristic voltage 2 [V]
p1324
Characteristic frequency 3 [Hz]
p1325
Characteristic voltage 3 [V]
p1326
Characteristic frequency 4 [Hz]
p1327
Characteristic voltage 4 [V]
p1330 CI: V/f control independent voltage setpoint
[100 % p2001]
p1331
Voltage limiting [V]
p1334 V/f control slip compensation starting frequency
[Hz]
p1335
Slip compensation, scaling [100 % r0330]
p1336
Slip compensation limit value [100 % r0330]
r1337
CO: Actual slip compensation [100 100%]
p1338 V/f mode resonance damping gain
p1340
I
max
frequency controller proportional gain
r1343 CO: I_max controller frequency output
[100 % p2000]
p1349 U/f mode resonance damping maximum
frequency [Hz]
p1351 CO: Motor holding brake starting frequency
[100 100%]
p1352 CI: Motor holding brake starting frequency
[100 100%]
r1438 CO: Speed controller speed setpoint
[100 % p2000]
p1452 Speed controller speed actual value smoothing
time (SLVC) [ms]