EasyManua.ls Logo

Siemens SINAMICS G120C - Page 52

Siemens SINAMICS G120C
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
4.2 Commissioning with BOP-2 operator panel
SINAMICS G120C converter
52 Getting Started, 04/2014, FW V4.7, A5E34264105B AA
r2053
PROFIdrive diagnostics send PZD word
[0]
PZD 1
[7]
PZD 8
r2054
PROFIBUS status
0
Off
1
No connection (search for baud rate)
2
Connection OK (baud rate found)
3 Cyclic connection with master (data
exchange)
4
Cyclic data OK
r2055
PROFIBUS diagnosis standard
[0]
Master bus address
[1]
Master input total length bytes
[2]
Master output total length bytes
r2057
PROFIBUS address switch diagnostics
r2060
CO: IF1 PROFIdrive PZD receive double word
[0]
PZD 1 + 2
[10]
PZD 11 + 12
r2061 CI: IF1 PROFIdrive PZD send double word
[0]
PZD 1 + 2
[10]
PZD 11 + 12
r2063 IF1 PROFIdrive diagnostics PZD send double
word
[0]
PZD 1 + 2
[10]
PZD 11 + 12
r2067
IF1 PZD maximum interconnected
[0]
Receiving
[1]
Sending
p2072
Response, receive value after PZD failure
.00 Unconditionally open
holding brake (p0855)
1 = freeze value
0 = zero value
r2074
PROFIdrive diagnostics bus address PZD receive
[0]
PZD 1
[7]
PZD 8
r2075 PROFIdrive diagnostics telegram offset PZD
receive
[0]
PZD 1
[7]
PZD 8
r2076
PROFIdrive diagnostics telegram offset PZD send
[0]
PZD 1
[7]
PZD 8
r2077 PROFIBUS diagnostics peer-to-peer data transfer
addresses
p2079
PROFIdrive PZD telegram selection extended
See p0922
p2080
BI: Binector-connector converter, status word 1
The individual bits are combined to form status
word 1.
p2088
Binector-connector converter, invert status word
r2089 CO: Send binector-connector converter status
word
[0]
Status word 1
[1]
Status word 2
[2]
Free status word 3
[3]
Free status word 4
[4]
Free status word 5
r2090
BO: PROFIdrive PZD1 receive bit-serial
r2091
BO: PROFIdrive PZD2 receive bit-serial
r2092
BO: PROFIdrive PZD3 receive bit-serial
r2093
BO: PROFIdrive PZD4 receive bit-serial
r2094
BO: Connector-binector converter binector output
r2095
BO: Connector-binector converter binector output
p2098 Invert connector-binector converter binector
output
p2099
CI: Connector-binector converter signal source
p2100
Setting the fault number for fault response
p2101
Setting the fault response
0
None
1
OFF1
2
OFF2
3
OFF3
5
STOP2
6
DC braking
p2103
BI: 1. Acknowledge faults
p2104
BI: 2. Acknowledge faults
p2106
BI: External fault 1
r2110
Alarm number
p2111
Alarm counter
p2112
BI: External alarm 1
r2122
Alarm code
r2123
Alarm time received [ms]
r2124
Alarm value
r2125 Alarm time removed [ms]
p2126
Setting fault number for acknowledge mode
p2127 Sets acknowledgement mode
p2128
Selecting fault/alarm code for trigger
r2129
CO/BO: Trigger word for faults and alarms
r2130
Fault time received in days
r2131
CO: Actual fault code
r2132
CO: Actual alarm code
r2133
Fault value for float values
r2134
Alarm value for float values
r2135
CO/BO: Status word, faults/alarms 2
r2136
Fault time removed in days

Other manuals for Siemens SINAMICS G120C