Table 10-67 PM240-2, PT, frame size D, 500 V to 690 V 3 AC
Article No. without filter
Article No. with filter
6SL3211-1PH24-2UL0
6SL3211-1PH24-2AL0
LO base load power 37 kW
LO base load input current 40 A
LO base load output current 42 A
HO base load power 30 kW
HO base load input current 36 A
HO base load output current 35 A
Fuse according to IEC
Fuse according to UL, class J
33NA3822-6 (63 A)
60 A
Power loss without filter 0.93 kW
1)
Power loss with filter 0.94 kW
1)
Required cooling air flow 55 l/s
Weight without filter 20.5 kg
Weight with filter 22.5 kg
1)
approx. 0.8 kW through the heatsink
Table 10-68 PM240-2, IP20, frame size E, 500 V … 690 V 3 AC
Article No. - without filter
Article No. - with filter
6SL3210-1PH25-2UL0
6SL3210-1PH25-2AL0
6SL3210-1PH26-2UL0
6SL3210-1PH26-2AL0
LO base load power 45 kW 55 kW
LO base load input current 50 A 59 A
LO base load output current 52 A 62 A
HO base load power 37 kW 45 kW
HO base load input current 44 A 54 A
HO base load output current 42 A 52 A
Siemens fuse according to IEC/UL
Fuse according to IEC/UL, Class J
3NA3824-6 (80A)
80 A
3NA3824-6 (80A)
80 A
Power loss without filter 1.07 kW 1.30 kW
Power loss with filter 1.08 kW 1.31 kW
Required cooling air flow 83 l/s 83 l/s
Weight without filter 26 kg 26 kg
Weight with filter 28 kg 28 kg