3.9.2 Electrical interfaces
Auxiliary supply and signals
15-pin interfaces for the auxiliary power supply and signals are available at the input and output.
Figure 3-8 Auxiliary supply and signal interfaces
See also
Laying the signal lines (Page 72)
3.9.3 DRIVE-CLiQ interface
Table 3-2 DRIVE-CLiQ interface
Pin Signal name Technical data
1 TXP Transmit data +
2 TXN Transmit data -
3 RXP Receive data +
4 Reserved, do not use
5 Reserved, do not use
6 RXN Receive data -
7 Reserved, do not use
8 Reserved, do not use
Description
3.9 Interfaces
SINAMICS SH150 6SL3805
40 Operating Instructions 05/2020