Remedy
1.
Check the preset service maintenance plan and make the relevant preparations.
+
2.
Select the system data operating area.
3.
Press this key on the PPU to access the extended softkeys.
4.
Enter the main screen of service planning.
5.
Press this softkey on the PPU to cancel the alarm.
4.1.9
Alarm 700030
Alarm description
It is not a fault but a reminder that the time is up for the first service plan preset on the control system. You need to execute
the service plan immediately.
PLC information
PLC address: DB1600.DBX3.6
Subroutine: PI_SERVICE (SBR 46)
Remedy
+
1.
Select the system data operating area.
2.
Press this key on the PPU to access the extended softkeys.
3.
Enter the main screen of service planning.
4.
Press this softkey on the PPU after executing the relevant service plan to cancel the alarm.
4.1.10
Alarm 700060
Alarm description
It is not possible to change the program test state on the control system during program execution. You must first place the
control system to the reset state.
PLC information
PLC address: DB1600.DBX7.4
Subroutine: MCP_NCK (SBR 37)

Other manuals for Siemens SINUMERIK 808D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D and is the answer not in the manual?

Siemens SINUMERIK 808D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D
CategoryControl Unit
LanguageEnglish

Related product manuals