EasyManua.ls Logo

Siemens SINUMERIK 840DE

Siemens SINUMERIK 840DE
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
03.06
4.1 Components
4-38
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition
Table 4-2 Components from the NCU 5xx.4 series:
NCU
Order no. (MLFB) Processor CNC user
memory
min. / max.
PLC PLC
memory
min. / max.
Front
plate
Fan
box
561.4 6FC5356-0BB12-
0AE0
AMD K6-2
233 MHz
0.5/2.5 MB *) PLC 314C-2DP 96 / 480 KB Type 2 No
561.4 6FC5356-0BB14-
0AA0
Celeron
400 MHz
0.5/3 MB *) PLC 314C-2DP 96 / 480 KB Type 3 No
571.4 6FC5357-0BB12-
0AE0
AMD K6-2
233 MHz
0.5/2.5 MB *) PLC 314C-2DP 96 / 480 KB Type 2 No
571.4 6FC5357-0BB14-
0AA0
Celeron
400 MHz
0.5/3 MB *) PLC 314C-2DP 96 / 480 KB Type 3 No
572.4 6FC5357-0BB23-
0AE0
AMD K6-2
233 MHz
0.5/2.5 MB *) PLC 314C-2DP 96 / 480 KB Type 2 No
572.4 6FC5357-0BB24-
0AA0
Celeron
400 MHz
0.5/3 MB *) PLC 314C-2DP 96 / 480 KB Type 3 No
573.4 6FC5357-0BB34-
0AE0
Pentium III
500 MHz
2.5/2.5 MB *) PLC 314C-2DP 96 / 480 KB Type 3 Yes
573.4 6FC5357-0BB34-
0AE1
Celeron
650 MHz
2.5/2.5 MB *) PLC 314C-2DP 96 / 480 KB Type 3 No
573.4 6FC5357-0BB34-
0AA0
Celeron
650 MHz
2.5/3 MB *) PLC 314C-2DP 96 / 480 KB Type 3 No
*) With technological cycles and measuring cycles, max. 1.5 MB available for users. With ShopMill/ShopTurn 1.2 MB
available to users in the basic configuration and no other CNC user memory options are possible.
Table 4-3 Components from the NCU 5xx.5 series:
NCU
Order no. (MLFB) Processor CNC user
memory
min. / max.
PLC PLC
memory
min. / max.
Front
panel
Fan
box
561.5 6FC5356-0BB15-
0AA0
Celeron
400 MHz
3 **) / 6 MB PLC 317-2DP 128 / 768 KB Type 3 No
571.5 6FC5357-0BB15-
0AA0
Celeron
400 MHz
3 **) / 6 MB PLC 317-2DP 128 / 768 KB Type 3 No
572.5 6FC5357-0BB25-
0AA0
Celeron
650 MHz
3 **) / 6 MB PLC 317-2DP 128 / 768 KB Type 3 No
573.5 6FC5357-0BB35-
0AE0
Pentium III
933 MHz
3 **) / 6 MB PLC 317-2DP 128 / 768 KB Type 3 No
573.5 6FC5357-0BB35-
0AA0
Pentium III
933 MHz
3 **) / 6 MB PLC 317-2DP 128 / 768 KB Type 3 No
**) Available to the user in the basic configuration:
– with technological cycles and measuring cycles max. 1.5 MB
– with ShopMill/ShopTurn 1.2 MB
Features of the NCU modules:
Standard PCMCIA card
4 High-speed NC inputs and 4 rapid NC outputs
2 Measuring pulse inputs
2 Handwheel inputs
Voltage and temperature monitoring
4 Descri
p
tion of the NCU

Other manuals for Siemens SINUMERIK 840DE