03.06
5.1 Single I/O module
5-65
© Siemens AG, 2006. All rights reserved
SINUMERIK 840D Configuring Manual NCU (PHD) – 03.06 Edition
Table 5-1 Technical data of the single I/O module
Power supply
for LOGIC (X1) and POWER (X5)
– Nominal value
– Perm. range
– Ripple
– Polarity reversal protection
– Fuse-protection
Current consumption – LOGIC
– POWER
Power loss – LOGIC
– POWER
DC 24 V
18.5 ... 30.2 V
3.6 V ss
yes
LOGIC: 1 A/250 V
POWER: no
type: 0.3 A , max. 1 A
max. 12 A
type: 7.2 W, max. 30.2 W
max: 362 W
Inputs
Number of inputs
Signal level for signal “0”
Signal level for signal “1”
Isolation
64 digital inputs
–3 V to + 5 V
+ 15 V to +30 V
yes (optocoupler)
Input current 0-signal
Delay time T
PHL
Delay time T
PLH
Noise immunity (DIN 57847)
Cable length terminal block
–9 mA to 1 mA
0.5 to 3 ms
0.5 to 3 ms
2 kV
max. 3 m
Outputs
Number of outputs
Signal level for signal “0”
Signal level for signal “1”
Isolation
Short-circuit-proof
Max. output current
Switching frequency
Noise immunity (DIN 57847)
Cable length terminal block
32 digital outputs
open
U
Power
– 0.5 V
yes (optocoupler)
yes
resistive: 0.6 A
inductive: 0.6 A
lamp: 6 W
ohmic load: 100 Hz
inductive load: 2 Hz
lamp load: 11 Hz
2 kV
max. 3 m
Overtemperature protection block-specific shutdown
Coincidence factor
Total of all nominal currents within each
group of 0.5 A
75%
Degree of protection IP20 or IPXXB
Weight 1.7 kg
Technical data
5 I/O Modules