Group Setting Description
Authentication Admin User User name of the administrator. The administrator can
add or delete users and assign or delete user authoriza‐
tions.
Password Password of the administrator.
Confirm Password Enter the password again for confirmation.
Allow anonymous ac‐
cess
Standard configuration: Deactivated
Anonymous access is only recommended for commis‐
sioning.
Accept certificates au‐
tomatically
Standard configuration: Activated
If this option is set, all client certificates are automatically
accepted. For manual acceptance, please refer to chap‐
ter Certificate handling (Page 22).
Activation Activate OPC UA Place the checkmark to activate OPC UA and remove
the checkmark to deactivate it.
NOTICE
Security risk due to data manipulation and data sniffing
Anonymous access can be a security risk. Anonymous access should therefore be strictly
limited to commissioning.
For normal operation authentication via username and password or based on
certificates should be used (see chapter Certificate handling (Page 22)).
NOTICE
Security risk due to data manipulation and data sniffing
If no message encryption to the client is established, there will be a security risk of data
manipulation and data sniffing. It is therefore highly recommended to establish a message
encryption to the client.
Use the highest possible encryption standard (256 bit) to ensure a secure message
transfer.
Setting up of OPC UA server
3.3 Commissioning
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
20 Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0