4. Follow the installation instructions.
5. After successful installation, restart the NCU/PPU.
Note
If OPC UA was active before the installation, users and rights will be preserved.
7.3 Compatibility
Compatibility
Below are the compatibility issues of OPC UA:
Password
The Password length has changed to min. 8 characters.
User rights
The behavior in setting “SinuReadAll” and “SinuWriteAll” is different from previous
versions.
Different from previous version is that removing the right “SinuReadAll” will remove all
read rights. In previous versions additionally added read rights have not been deleted
with removing “SinuReadAll”.
Same applies to “SinuWriteAll”.
Note
If you face any other compatibility issues or for further details, refer to hotline (https://
support.industry.siemens.com/cs/sc/2090/).
Update of OPC UA Server
7.3 Compatibility
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
68 Configuration Manual, 04/2018, 6FC5397-1DP41-0BA0