Accessories
10.3 Mechanical remote RESET
SIRIUS 3RU thermal overload relays / SIRIUS 3RB electronic overload relays
Manual, 09/2016, A5E03656507420A/RS-AB/003
129
10.3
Mechanical remote RESET
Available versions
A mechanical remote reset option is also available for thermal overload relays and solid-
state overload relays. There are two options for mechanical remote RESET:
Release slide (Page 129)
Cable release with holder for built-in overload relays which are hard to reach (Page 131)
10.3.1
Release slide
10.3.1.1
Description
Release slide
There is one release slide for thermal overload relays and one for solid-state overload relays;
both are compatible for use with all sizes. The release slide with holder and former is used to
activate the RESET from the control cabinet door; it is shortened to the required length. A
pushbutton with extended travel and an extension plunger for compensation of the distance
between the pushbutton and the relay's unlocking button are available for the release slide.