EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 User Manual

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
Industrial Controls
Command and signaling devices
SIRIUS ACT 3SU1 pushbuttons
and signaling devices
System Manual
08/2018
A5E03457306020A/RS
-AK/010
Introduction
1
Safety notes
2
ATEX for intrinsically safe
circuits
3
Overview
4
3SU10 pushbuttons and
indicator lights
5
3SU11 complete units
6
3SU12 compact units
7
3SU14 modules
8
3SU15 holders
9
3SU18 enclosures
10
AS-Interface 3SU14
11
IO-Link 3SU14
12
3SU19 accessories
13
Technical specifications
14
Dimension drawings
15
Application examples
16
Appendix
A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIRIUS ACT 3SU1 and is the answer not in the manual?

Siemens SIRIUS ACT 3SU1 Specifications

General IconGeneral
BrandSiemens
ModelSIRIUS ACT 3SU1
CategoryControl Unit
LanguageEnglish

Summary

1 Introduction

1.1 Responsibility of the user for system configuration and functionality

User's responsibility for system configuration, functionality, and compliance with safety instructions.

1.2 Target group

Identifies decision makers, technologists, project planners, and commissioning engineers as the target audience.

1.4 Required knowledge

Lists general knowledge areas needed to understand the documentation, including industrial controls and safety technology.

2 Safety notes

2.1 Intended use

Specifies the proper application of devices, including warnings about hazardous voltage and proper installation.

2.3 Security information

Provides guidance on industrial security functions and protecting systems against cyber threats.

3 ATEX for intrinsically safe circuits

4 Overview

4.1 Overview of the device range

Presents a comprehensive overview of the SIRIUS ACT pushbuttons, indicator lights, modules, enclosures, and consoles.

4.2 Application areas

Details the application areas for enclosures and specific device types like EMERGENCY STOP.

4.5 Types of 3SU1 actuating elements and signaling elements

Describes the various types of actuating and signaling elements available for the 3SU1 series.

5 3SU10 pushbuttons and indicator lights

5.1 3SU10 devices for use on 3-slot holder

Describes 22.5 mm and 30.5 mm pushbuttons, including variants and article numbers.

5.1.9 EMERGENCY STOP mushroom pushbuttons

Details the features and compliance of EMERGENCY STOP mushroom pushbuttons with ISO 13850.

5.3 Mounting

Provides instructions for mounting actuators and signaling elements, including front plate and PCB mounting.

6 3SU11 complete units

6.1 Product description

Introduces the 3SU11 complete units as modular devices for front plate and rear cable connection.

6.2 3SU11 devices for use on 3-slot holder

Covers pushbuttons, illuminated pushbuttons, mushroom pushbuttons, and indicator lights for 3-slot holders.

6.2.4 EMERGENCY STOP mushroom pushbuttons

Details the features and compliance of EMERGENCY STOP mushroom pushbuttons with DIN EN ISO 13850.

7 3SU12 compact units

7.1 Overview

Describes the integrated electrical functions of 3SU12 compact units and lists available types.

7.1.1 Indicator lights

Details indicator lights function as indicators and signaling devices, available in different variants.

7.1.6 Sensor switches

Details sensor switches used for operating machines or as door opening switches, emphasizing durability.

8 3SU14 modules

8.1 Overview

Introduces contact modules, LED modules, test modules, ASIsafe F adapters, and AS-Interface modules.

8.1.3 Contact modules for front plate mounting

Explains contact modules with gold contacts for better corrosion resistance and high reliability.

8.1.7 LED modules

Covers LED modules with integrated LEDs for illumination, available in different variants.

8.1.17 Electronic modules for ID key-operated switches

Details electronic modules for ID key-operated switches, including IO-Link compatibility and installation.

9 3SU15 holders

9.1 Holders

Describes holders used to secure actuating or signaling elements and contact/LED modules, with details on slot positions.

10 3SU18 enclosures

10.1 Enclosures for actuating and signaling elements

Lists available plastic and metal enclosures with 1 to 6 command points, detailing colors and variants.

10.2 Enclosures with EMERGENCY STOP devices

Covers enclosures with integrated EMERGENCY STOP pushbuttons, their certification, and safety circuits.

10.4 3SU18..-3 two-hand operation console

Explains the application areas and function of two-hand operation consoles for machine safety.

11 AS-Interface 3SU14

11.1 Application areas

Describes the use of AS-Interface modules for connecting distributed SIRIUS ACT pushbuttons to the AS-Interface bus.

11.2 ASIsafe F adapters for front plate mounting

Details ASIsafe F adapters for quick connection of SIRIUS ACT devices to AS-Interface, supporting safety-related communication.

11.5 Enclosure with standard equipment for AS-Interface

Describes enclosures equipped with AS-Interface modules and slaves for connecting contact and LED modules.

11.9 Connecting

Covers connection options for AS-Interface modules, including conventional and safe connections.

12 IO-Link 3SU14

12.1 Configuring the IO-Link

Explains how to configure IO-Link masters and devices using STEP 7 and S7-PCT.

12.2 Electronic modules for ID key-operated switches

Details the design and operating principles of electronic modules for ID key-operated switches.

12.3 Electronic modules for IO-Link

Describes the functions, parameters, and variants of electronic modules for IO-Link.

12.3.4 Diagnostics

Covers IO-Link diagnostics, including possible causes and remedial measures for faults.

13 3SU19 accessories

13.2 Identification of command points

Details backing labels, backing plates, labeling plates, and insert labels for identifying command points.

13.3 Protection

Covers protective caps, dust caps, and sun collars for protecting actuators against environmental factors.

13.3.8 Locking device

Explains locking devices designed to prevent unauthorized actuation of pushbuttons and switches.

13.4 Actuators

Lists available actuators for pushbuttons and indicator lights, categorized by button and front ring material.

13.5 Keys

Provides an overview of available keys for key-operated switches, categorized by manufacturer and type.

13.6 ID keys

Details ID keys used with ID key-operated switches, including authorization levels and color coding.

13.10 Accessories for enclosures

Lists various accessories for enclosures, including cable glands and connection pieces.

13.13 Use of accessories for the enclosure

Details instructions for using accessories with enclosures, including those with and without labeling plate recesses.

14 Technical specifications

14.1 Technical data in Siemens Industry Online Support

Guides users on how to find technical data for products via Siemens Industry Online Support.

14.2 Pushbuttons

Provides technical specifications for various pushbutton types, including mechanical durability and ambient temperature.

14.4 EMERGENCY STOP mushroom pushbuttons

Details technical specifications for EMERGENCY STOP mushroom pushbuttons, including compliance with ISO 13850.

14.7 Key-operated switches

Lists technical specifications for key-operated switches, covering durability, shock resistance, and ambient temperature.

15 Dimension drawings

15.1 CAx data

Guides users on how to find CAx data for products on Siemens Industry Online Support.

15.2 Mounting dimensions

Provides minimum clearances and mounting dimensions for various devices and holders.

15.3 3SU10 devices

Shows dimension drawings for 3SU10 pushbuttons, STOP buttons, twin pushbuttons, and mushroom pushbuttons.

15.5 3SU14 modules

Displays dimension drawings for 3SU14 modules, including contact modules and LED modules.

15.7 3SU18 enclosures

Shows dimension drawings for 3SU18 enclosures, including plastic and metal variants with different command points.

15.8 Accessories

Lists various accessories for enclosures, such as adapters, mounting kits, and cover monitoring.

16 Application examples

16.1 Examples of EMERGENCY STOP shutdown applications

Illustrates emergency stop shutdown applications using safety relays and AS-Interface with modular safety systems.

16.2 Examples of two-hand operation console applications

Provides examples of two-hand operation console applications, including wall-mounted and safety relay configurations.

16.3 Application examples for ID key-operated switches

Shows application examples for ID key-operated switches in machine tool and production line scenarios.

A Appendix

A.1 Process data and data sets

Details process data and data sets for electronic modules, including ID key-operated switches and IO-Link communication parameters.

A.1.1.4 System commands - data set (index) 2

Lists system commands and their functions for managing authorization levels and ID keys.

A.1.2 IO-Link communication parameters

Lists IO-Link communication parameters, including master and device specifications and differences between versions.

Related product manuals