Appendix
A.1 Process data and data sets
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
587
A.1.1.14 Parameters - Data set (index) 131 (from FW 2.0.0)
Data set (index) 131 (parameters)
Note
Bits that are not described in the tables below are reserved and should be ignored.
Table A- 14 Data set (index) 131 (parameters)
Byte.Bit Subindex Description
Operating system functions
0.0 ... 15.7 1 ... 3 Reserved
16.0 4 Switch in stages
Default: [0]
[0] disabled
[1] enabled
16.1 5 Switch position memory
Default: [0]
[0] disabled (key position = 0)
[1] enabled (last key position is retained)
16.2
6 Switch position retentive memory:
Default: [0]
[0] disabled
[1] enabled
16.3
7 Individually encodable ID keys only:
Default: [0]
[0] disabled
[1] enabled
17.0 ... 17.7 8 Switch position delay
Type: 8-bit unsigned (byte)
Resolution: 0.1 s = 1
Default: 20
Min: 1 or 0 (disabled)
Max: 100 * 0.1 s = 10 s
18.0 ... 18.7 9 Select memory range
Default [1]
Min: 1
Max: 5
19.0 10 Deactivation of the switch-off function
Default [0]
[0] A counter-clockwise rotation immediately switches off DQ.0 – DQ.3
[1] The counter-clockwise rotation reduces the switch position by one, according to the level
of the inserted ID key
19.1 ... 19.7 Reserved