Technical specifications
14.14 Contact modules
SIRIUS ACT 3SU1 pushbuttons and signaling devices
452 System Manual, 08/2018, A5E03457306020A/RS-AK/010
14.14
Contact modules
Type
3SU1400-.....-1
3SU1400-.....-3
3SU1400-.....-5
Insulation voltage,
rated value
V 500
Pollution degree
3
Rated impulse withstand voltage,
rated value
kV 6
Operating voltage type
AC/DC
Operating voltage
At AC
Rated value
V
5 ... 500
At DC
Rated value
V
5 ... 500
Thermal current
A
10
Operational current, rated value
At AC-12
At 24 V
At 230 V
A
A
10
8
At AC-15
At 24 V
At 230 V
At 400 V
At 500 V
A
A
A
A
6
6
3
1.4
At DC-12
At 24 V
At 48 V
At 110 V
At 230 V
At 400 V
At 500 V
A
A
A
A
A
A
10
5
2.5
1
0.3
0.3
At DC-13
At 24 V
At 48 V
At 110 V
At 230 V
At 400 V
At 500 V
A
A
A
A
A
A
3
1.5
0.7
0.3
0.1
0.1