"Incremental switching mode" parameter
"Incremental switching mode" parameter
The "Incremental switching mode" parameter influences the evaluation of the current key
position.
1) "Incremental switching mode" disabled: The adjustment method is used.
● Key position ≥ 1: The output corresponding to the current key position-1 is switched on;
the remaining outputs 0 ... 3 are inactive.
● Key position 0: All outputs 0 ... 3 are inactive.
Example: Key position = 2: Output 0: Off, output 1: On, output 2: Off, output 3: Off
2) "Incremental switching mode" enabled: The addition method is used.
● Key position ≥ 1: The outputs with the indices from 0 to the current switch position-1 are
switched on; the remaining outputs 0 ... 3 are inactive.
● Key position 0: All outputs 0 ... 3 are inactive.
Example: Key position = 2: Output 0: On, output 1: On, output 2: Off, output 3: Off
Incremental switching mode: disabled
Incremental switching mode: enabled
"Deactivation of the switch-off function" parameter
"Deactivation of the switch-off function" parameter
The "Deactivation of the switch-off function" parameter is used to define whether or not the
selected authorization level can be deactivated by turning to the left.
The table below shows the parameter values.
The authorization levels are switched off by turning to the left.
Enabled The authorization levels are switched off by turning to the left.
The next lower authorization level can be selected directly
—