EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 - Application Areas for AS-Interface Modules for Front Plate Mounting

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AS-Interface 3SU14
11.1 Application areas
SIRIUS ACT 3SU1 pushbuttons and signaling devices
254 System Manual, 08/2018, A5E03457306020A/RS-AK/010
AS-Interface standard modules (slave 4I/4O and A/B slave 4I/3O)
Mounted in a 3SU1 enclosure, the AS-Interface module modules 4I/4O and 4I/3O can query
4 mechanical contacts. The AS-Interface module 4I/4O also enables control of 4 indicator
lights, while the module 4I/3O enables control of 3 indicator lights. The power required is
supplied by the AS-Interface system. In conjunction with an A/B-compatible AS-Interface
master, up to 62 x 4I/3O modules can be operated in one AS-Interface network.
11.1.2
Application areas for AS-Interface modules for front plate mounting
The AS-Interface modules for front plate mounting are used to connect an EMERGENCY
STOP device from the SIRIUS ACT series to the AS-Interface bus system according to
ISO 13850. The modules for front plate mounting are suitable for pushbuttons with front plate
mounting.
The AS-Interface modules for front plate mounting have a safe AS-Interface slave 2I and are
snapped onto the holder from behind.
The expanded version 2I/1O includes an output for controlling a signaling element with LED.
Depending on the version, the connection to the AS-Interface bus cable is by means of
screw terminals, spring-loaded terminals or insulation displacement method. Addressing is
performed using the AS-Interface connection or the integrated addressing socket.
With the modules for front plate mounting, applications up to SILCL 3 as per IEC 62061,
SIL 3 as per IEC 61508 and PL e (Cat. 4) as per ISO 13849-1 can be implemented
depending on the connection of evaluation unit and actuators.

Table of Contents