EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 - A.1.1.4 System commands - data set (index) 2

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix
A.1 Process data and data sets
SIRIUS ACT 3SU1 pushbuttons and signaling devices
578 System Manual, 08/2018, A5E03457306020A/RS-AK/010
A.1.1.4
System commands - data set (index) 2
Data set (index) 2 - system commands
Table A- 4 Data set (index) 2 - system commands
Data set
Access
Parameter
Length
(bytes)
Default setting
Index (dec)
0x02 (2) w System Command
1)
1
1)
Permissible vendor-specific system commands (firmware-specific):
FW 1.4.0 (or FW 2.0.0 in
compatibility mode)
FW 2.0.0 supported command
Set authorization level 1
(system command 161 (0xA1))
YES NO
Set authorization level 2
(system command 162 (0xA2))
YES NO
Set authorization level 3
(system command 163 (0xA3))
YES NO
Set authorization level 4
(system command 164 (0xA4))
YES NO
Delete individually encodable ID
key
(system command 165 (0xA5))
YES YES
Delete individually encodable ID
key using data set 80
(system command 166 (0xA6))
YES YES
Delete all ID keys
(system command 167 (0xA7))
YES YES
Add inserted ID key
(system command 168 (0xA8))
NO YES
Add ID key using its number
(system command 169 (0xA9))
NO YES
The new, individually encodable ID key can be added on the basis of the following system
commands:
Add ID key - system command
System command: Index: 2, subindex: 0
168 [0xA8]hex Add inserted ID key
169 [0xA9]hex
Add ID key using its number
These new system commands are not supported in compatibility mode.