IO-Link 3SU14
12.2 Electronic modules for ID key-operated switches
SIRIUS ACT 3SU1 pushbuttons and signaling devices
326 System Manual, 08/2018, A5E03457306020A/RS-AK/010
12.2.5.8
"Select memory range" parameter
"Select memory range" parameter
The Port Configuration Tool
S7-PCT
includes a dropdown menu with which you can select
the part of the data set to be displayed. The memory range in which the individually codable
ID keys are saved can be selected and displayed.
Settings
Description
Default setting
1
Select memory range: Minimum value
1 (individually codable key 1 ... 10)
5
Select memory range: Maximum value
Increment: 10 keys
12.2.5.9
"Restore Factory Setting” parameter
"Restore Factory Setting" parameter
In some situations, the electronic module for ID key-operated switches for IO-Link has to be
changed to the standard state quickly and simply. For this purpose, the standardized system
command "Restore Factory Setting" (value 0x82 in the data set (index) 2 - system
commands or the button in the Port Configuration Tool
S7-PCT
) is used.
This command triggers the following:
Standard settings for parameters - data set (index) 131
Deleting the list of keys
Data set (index) 24 (Application Specific Name) is deleted
Settings
Description
130
Restore Factory Setting
Standard values for parameters - data set (index) 131
Parameters
Setting
Incremental switching mode
Disabled
Switch position memory
Disabled
Switch position retentive
memory
Disabled
Individually codable ID keys
only
Disabled
Deactivation of the switch-off
function
Disabled
Switch position delay
20 (2 seconds)
Select memory range
1 (individually codable key 1 ... 10)