EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 - Process Image

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IO-Link 3SU14
12.2 Electronic modules for ID key-operated switches
SIRIUS ACT 3SU1 pushbuttons and signaling devices
334 System Manual, 08/2018, A5E03457306020A/RS-AK/010
12.2.6
Process image
Process image input (PII)
The process image input contains the most important status information of the electronic
modules for the ID key-operated switch for IO-Link.
Table 12- 5 PII - status information firmware version 1.4.0
DI (2 bytes)
PII
DI0.0
1: Ready
DI0.1 1: Group error
DI0.2
Reserved
DI0.3 Reserved
DI0.4
Reserved
DI0.5
Reserved
DI0.6
Reserved
DI0.7
Reserved
DI1.0
1: ID key recognized
DI1.1 - DI1.3
1: Authorization level
DI1.4 - DI1.6
1: Switch position
Table 12- 6 PII - status information as of firmware version 2.0.0
DI (2 bytes)
PII
DI0.0
Ready
DI0.1
Group error
DI0.2
Inserted ID key - Authorization level 1
DI0.3
Inserted ID key - Authorization level 2
DI0.4
Inserted ID key - Authorization level 3
DI0.5
Inserted ID key - Authorization level 4
DI0.6
Reserved
DI0.7
Reserved
DI1.0
ID key recognized
DI1.1
Digital output 0
DI1.1
Digital output 1
DI1.3 Digital output 2
DI1.4
Digital output 3
DI1.5 Digital output 4
DI1.6
Reserved
DI1.7
Reserved
In compatibility mode, the process image is identical to FW 1.4.0.

Table of Contents