Appendix
A.1 Process data and data sets
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
585
A.1.1.11
Diagnostics - data set (index) 94
Data set (index) 94 (ID keys)
Note
Bits that are not described in the tables b
elow are reserved and should be ignored.
Table A- 11 Data set (index) 94 (ID keys)
Byte.Bit
Subindex
Description
0.0 ... 15.7
1 ... 3
Reserved
16.0 ... 20.7
4
Identification number of the individually codable ID key
21.0 ... 21.2
5
Authorization level
21.3 ... 21.5
6
Key position
A.1.1.12
Diagnostics - dataset (index) 94 (FW 2.0.0 or higher)
Data set (index) 94 (ID keys)
Note
Bits that are not d
escribed in the tables below are reserved and should be ignored.
Table A- 12 Data set (index) 94 (ID keys)
Byte.Bit
Subindex
Description
0.0 ... 15.7
1 ... 3
Reserved
16.0 ... 20.7 4 Identification number of the individually codable ID key
21.0 … 21.3
5
Authorization level
21.4 … 21.7 6 Key position