Technical specifications
14.10 Acoustic signaling devices
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
449
14.10
Acoustic signaling devices
Type
3SU1...-6K
Voltages (AC/DC)
V 24
110
230
Volume level
dB
75
Switching frequency maximum
1/h
1800
Shock resistance
according to IEC 60068-2-27
11 ms, 50g, half-sine
Vibration resistance
according to IEC 60068-2-6
10 ... 500 Hz: 5g
Degree of protection
IP
IP40
Ambient temperature
during operation
°C -25 … +70
during storage
°C -40+80
14.11
Potentiometers
Type
3SU1...-2P
Mechanical durability (operating cycles) typical
25000
Switching frequency maximum
1/h
1800
Relative accuracy of the resistor
%
10
Shock resistance
according to IEC 60068-2-27
11 ms, 50g, half-sine
Vibration resistance
according to IEC 60068-2-6
10 ... 500 Hz: 5g
Degree of protection
IP
IP66, IP67, IP69
Ambient temperature
during operation
°C -25 … +70
during storage
°C -40+80