Loading...
3SU10 pushbuttons and indicator lights
5.3 Mounting
SIRIUS ACT 3SU1 pushbuttons and signaling devices
116 System Manual, 08/2018, A5E03457306020A/RS-AK/010
5.3.6
Mounting a command point with ID key-operated switch
Procedure
1. Insert the ID key-operated switch from the front into the opening of the front plate.
2. Place the holder from behind onto the ID key-operated switch.
3. Tighten the screw on the holder (tightening torque 1.0 to 1.2 Nm).
4. Snap the electronic module for ID key-operated switch onto the back of the holder.
Fit the narrow snap hook into the associated contour on the holder.
5. Engage the broad snap hook into the associated contour on the holder.
Ensure secure latching.
Snapping an electronic module onto the holder /

Table of Contents