EasyManua.ls Logo

Siemens SIRIUS ACT 3SU1 - A Appendix; A.1 Process data and data sets

Siemens SIRIUS ACT 3SU1
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
575
Appendix
A
A.1
Process data and data sets
A.1.1
Electronic module for ID key-operated switches
A.1.1.1
Structure of the data sets
Overview of the data sets
Table A- 1 Data sets - overview
Data set
Name
Access
Value
Length
(bytes)
Index
(dec)
Index
(hex)
Subindex
supported
0
0
Yes
Parameter Page 1
r / w
16
2 2 Yes System Command w 1
3
3
Yes
Data Storage
r / w
24
12 0C No Device Access locks r / w 2
16
10
No
Vendor Name
r
Siemens AG
10
17 11 No Vendor Text r Internet
(
http://support.automation.siemens.co
m/WW/view/en/29801139/130000)
64
18 12 No Product Name r SIRIUS ACT electronic module for
ID key-operated switch
55
19
13
No
Product ID
r
3SU1400-1GD10-1AA0
18
23
17
No
Firmware Revision
r
5
24
18
No
Application Specific Name
r / w
32
69
45
Yes
Process Data In
r
6
79 4F Yes Add individually encodable
ID key
Dataset 79
r / w 6
80 50 Yes Delete individually codable
ID key, data set 80
r / w 5
81 51 Yes Memory for the individually
codable ID keys (1-30) data
set 81
r 180
82 52 Yes Memory for the individually
codable ID keys (31-50)
data set 82
r 120

Table of Contents