IO-Link 3SU14
12.3 Electronic modules for IO-Link
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
351
"Input delay” parameter
"Input delay
"
parameter
A delay time must be set at the input as a filter. Signal changes are ignored if they are
shorter than the parameterized values. The input values are delayed by the time set for the
filter. Values of between 3 and 255 ms can be set as the input delay.
Input delay: Minimum value
Input delay: Maximum value
"Inverting input” parameter
"Inverting input" parameter
Each input can be parameterized as a normal or an inverting input.
0 Inverting input: disabled disabled
"Switching input” parameter
"Switching input” parameter
Target value with which the actual switching cycle number is compared. The number of
switching cycles can be set to between 0 and 4 294 967 295 (0xFFFFFFF [hex]).
Number of switching cycles: Minimum value
Number of switching cycles: Maximum value