Installation
10
Siemens Building Technologies SISTORE AX4_EN.doc
Fire & Security Products 09.2004
NOTE:
The DVR may not support some LCD monitors or some monitors dont support Multi Sync.
NOTE:
You cannot use spot monitor output and VGA output at the same time.
NOTE:
Set the CVBS (SVHS) or VGA selector switch before turning on the DVR. You cannot change the
setting while the unit is running.
2.7 Connecting the Monitor
2.7.1 Connecting the Spot Monitor
Fig. 7 Video Out connectors.
Connect the SPOT monitor to either the Video Out or SVHS Out connector.
NOTE:
For SPOT monitor Output, set the CVBS (SVHS)/VGA selector switch to the CVBS (SVHS).
NOTE:
If your monitor has an SVHS input, use it because it will give you better quality video display.
NOTE:
The Video Out (BNC) and the SVHS Out connectors may be connected to individual monitors for
simultaneous operation.
2.7.2 Connecting the RGB Monitor
Fig. 8 VGA connector.
A VGA port is provided for RGB monitor output. Connect the RGB monitor to the
VGA connector if required. Connect an RGB cable with a DB-15 (male) connector,
which is usually less than 10 feet, to the DVR connector.
NOTE:
For RGB monitor output, set the CVBS (SVHS)/VGA selector switch to the VGA.