MAG 8000 & MAG 8000 CT
51
SFIDK.PS.026.D9.02
MAG 8000 CT MI-001 verified and labeled products at a given Q3 and Q3/Q4 = 1.25 and Q2/
Q1 = 6.3 measurering ranges se below table:
DN 50 65 80 100 125 150 200 250 300
(2“) (2½“) (3“) (4“) (5“) (6“) (8“) (10“) (12“)
„R“ Q3/Q1 25 25 25 25 25 25 25 25 25
Q4 [m
3
/h] 19 31 50 75 125 188 313 500 750
Q3 [m
3
/h] 15 25 40 60 100 150 250 400 600
Q2 [m
3
/h] 3.78 6.30 10.1 15.1 25.2 37.8 63.0 100.8 151.2
Q1 [m
3
/h] 0.60 1.00 1.60 2.40 4.0 6.0 10.0 16.0 24.0
DN 50 65 80 100 125 150 200 250 300
(2“) (2½“) (3“) (4“) (5“) (6“) (8“) (10“) (12“)
„R“ Q3/Q1 63 63 63 63 63 63 63 63 63
Q4 [m
3
/h] 19 31 50 75 125 188 313 500 750
Q3 [m
3
/h] 15 25 40 60 100 150 250 400 600
Q2 [m
3
/h] 1.50 2.50 4.0 6.0 10.0 15.0 25.0 40.0 60.0
Q1 [m
3
/h] 0.24 0.40 0.63 0.95 1.59 2.38 3.97 6.35 9.52
DN 50 65 80 100 125 150 200 250 300
(2“) (2½“) (3“) (4“) (5“) (6“) (8“) (10“) (12“)
„R“ Q3/Q1 63 63 63 63 63 63 63 63 63
Q4 [m
3
/h] 19 31 50 75 125 188 313 500 750
Q3 [m
3
/h] 15 25 40 60 100 150 250 400 600
Q2 [m
3
/h] 1.50 2.50 4.0 6.0 10.0 15.0 25.0 40.0 60.0
Q1 [m
3
/h] 0.24 0.40 0.63 0.95 1.59 2.38 3.97 6.35 9.52
The label is placed on the side of the encapsulation. An example of the product label is shown
below:
Note
Installation conditions for MAG 8000 CT has to be mounted in Integral (compact) and horizontal
position only, to obtain the MI-001 certification.
Battery packs must be installed with the top part in upwards direction to reach maximum capacity.
8. Technical data