EasyManua.ls Logo

Siemens SITRANS F M MAG 8000 CT User Manual

Siemens SITRANS F M MAG 8000 CT
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Manual
Edition 09/2007 - Revision 09
Order no.: FDK:521H1193
SFIDK.PS.026.D9.02
*083R9174*
SITRANS F M
Battery operated water meter type MAG 8000 & MAG 8000 CT
[
s
Technical Documentation (handbooks, instructions, manuals etc.) for the complete product
range SITRANS F can be found on the internet/intranet via the following link:
English:
http://www4.ad.siemens.de/WW/view/en/10806951/133300
]

Other manuals for Siemens SITRANS F M MAG 8000 CT

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS F M MAG 8000 CT and is the answer not in the manual?

Siemens SITRANS F M MAG 8000 CT Specifications

General IconGeneral
TypeElectromagnetic Flowmeter
Measurement PrincipleElectromagnetic
Nominal DiameterDN 25 to DN 1200
Temperature Range (Ambient)-20 to +60 °C
Output Signal4 to 20 mA
Power Supply24 V DC
Protection DegreeIP 68
Lining MaterialPTFE
Electrode MaterialStainless steel
MaterialStainless steel
ApprovalsATEX, IECEx

Summary

Introduction

User guidelines

Important safety and operational instructions for using the equipment and software.

Manufacturer's design and safety statement

Details on product design, safety, and battery handling precautions.

Installation

Mechanical installation

Guidelines for physical mounting, flow direction, and pipe conditions.

Bonding & grounding

Procedures for grounding the sensor body for electrical noise and lightning protection.

Maximum allowable torques

Specifies torque values for bolts to ensure proper installation and prevent leakage.

Electrical connection

Electrical installation

Details on connecting the meter to power and communication interfaces like RS232 and RS485.

IP enclosure rating

Procedures to maintain the meter's IP68/NEMA 6P enclosure rating, especially when using cable glands.

Commissioning

Connecting the PC to the meter

Steps to establish communication between a PC and the meter using IrDA interface.

Data protection by password

Information on the password protection feature for meter data and configuration.

Unit selection

Basic configuration for selecting volume and flow rate units.

Output configuration

Configuration options for pulse outputs, including volume, alarm, and call-up functions.

Parameter list

Details of meter parameters, their FT IDs, factory settings, and data ranges.

Operation

Meter operation via key and display

How to navigate the meter's display and operate it using the single interface key.

Operator menu

Explains the different indices available in the operator menu and their functions.

Operation on battery power

Details on battery management, capacity, and influencing factors.

Installation and replacement of batteries

Step-by-step guide for replacing the internal battery pack and ensuring proper sealing.

Verification

MAG 8000 CT sealing

Notes on user sealing for MAG 8000 CT verification.

Service

MAG 8000 & MAG 8000 CT service guidelines

General guidelines for meter service, troubleshooting, and problem detection.

Faults codes

Lists and explains various fault codes, their descriptions, and alarm reasons.

Replace a transmitter or PCB board

Guidance on replacing the transmitter or PCB board, including different replacement options.

Technical data

MAG 8000 & MAG 8000 CT

Comprehensive technical specifications for the meter, including accuracy, temperature, and approvals.

Meter uncertainty

Details on meter accuracy, calibration standards, and uncertainty specifications.

"Physical" dimension

Diagrams and tables detailing the physical dimensions and flange specifications of the meter.

Ordering

Accessories

List of available accessories for the meter, including order numbers and symbols.

Spare parts

List of spare parts available for the transmitter, PCB, and cables, with order numbers.

Approvals and certificates

Related product manuals