MAG 8000 & MAG 8000 CT
53
SFIDK.PS.026.D9.02
8. Technical data
8.7 The effect of tempe-
rature on working
pressure
Metric (Pressures in bar)
Sizes 25 mm, 40 mm & > 300 mm
Flange spec. Flange Temperature °C
rating 0105070
EN 1092-1 PN 10 10.0 10.0 9.7 9.4
PN 16 16.0 16.0 15.5 15.1
PN 40 40.0 40.0 38.7 37.7
ANSI 16.5 150 lb 19.7 19.7 19.3 18.0
Sizes 50 mm to 300 mm
EN 1092-1 PN 10 10.0 10.0 10.0 8.2
PN 16 10.0 16.0 16.0 13.2
ANSI 16.5 150 lb 10.0 19.7 19.7 16.2
Imperial (Pressures in Psi)
Sizes 1", 1½", & > 12"
Flange spec. Flange Temperature °F
rating 32 50 122 158
EN 1092-1 PN 10 145 145 141 136
PN 16 232 232 225 219
PN 40 580 580 561 547
ANSI 16.5 150 lb 286 286 280 261
Sizes 2" to 12"
EN 1092-1 PN 10 145 145 145 119
PN 16 145 232 232 191
ANSI 16.5 150 lb 145 286 286 235
8.8 “Physical”
dimension
Dimension mm [inch]
Nominal A L, lenghts D, diameter Weight
1)
size EN 1092-1 ANSI AS 4087 DI D O
DN PN PN PN 16.5 PN 16
10 16 40 Cl. 150
mm (inch) mm (inch) mm mm mm inch mm mm (inch) mm (inch) kg lbs
25 (1) 194 (7.7) - - 200 7.9 200 25 (0.98) See flange table 6 13
40 (1½) 204 (8.1) - - 200 7.9 200 40 (1.57) See flange table 9 20
50 (2) 195 (7.7) - 200 - 7.9 200 42 (1.65) See flange table 11 25
65 (2½) 201 (8) - 200 - 7.9 200 55 (2.17) See flange table 13 29
80 (3) 207 (8.2) - 200 - 7.9 200 67 (2.64) See flange table 15 34
100 (4) 214 (8.5) - 250 - 9.8 250 81 (3.19) See flange table 17 38
125 (5) 224 (8.9) - 250 - 9.8 250 101 (3.98) See flange table 22 50
150 (6) 239 (9.5) - 300 - 11.8 300 131 (5.16) See flange table 28 63
200 (8) 264 (10.5) 350 350 - 13.8 350 169 (6.65) See flange table 50 113
250 (10) 291 (11.5) 450 450 - 17.7 450 212 (8.35) See flange table 71 160
300 (12) 317 (12.6) 500 500 - 19.7 500 265 (10.43) See flange table 88 198
350 (14) 369 (14.6) 550 550 - 21.7 550 350 (13.78) See flange table 111 250
400 (16) 394 (15.6) 600 600 - 23.6 600 400 (15.75) See flange table 126 284
450 (18) 425 (16.8) 600 600 - 23.6 600 450 (17.72) See flange table 175 394
500 (20) 450 (17.8) 600 600 - 26.8 600 500 (19.68) See flange table 225 507
600 (24) 501 (19.8) 600 600 - 32.3 600 600 (23.62) See flange table 299 649
1)