2. Installation
Remote installation
Verify that the model and serial numbers shown on the labels of the sensor and transmitter are
matched properly (1). Make sure that the cable is safety installed to avoid damaging of cable and
connectors. Please note the different connector types for the coil and electrodes, both having a
minimum diameter of 90 mm (3.6 inches). Save the dust covers for future use and protection (2).
Make sure the connectors are clean and fastened securely to achieve a good connection and
watertight seal (3 & 4).
Note
If dirt enters the connector ends, use plain water for cleaning. Ensure the connectors are
completely dry before making connections.
mm inch Nm f/lbs Nm f/lbs Nm f/lbs Nm f/lbs
25 1" N/A N/A N/A N/A 10 7 7 5
40 1½" N/A N/A N/A N/A 16 12 9 7
50 2" N/A N/A 25 18 N/A N/A 25 18
65 2½" N/A N/A 25 18 N/A N/A 25 18
80 3" N/A N/A 25 18 N/A N/A 34 25
100 4" N/A N/A 25 18 N/A N/A 26 19
125 5" N/A N/A 29 21 N/A N/A 42 31
150 6" N/A N/A 50 37 N/A N/A 57 42
200 8" 50 37 50 37 N/A N/A 88 65
250 10" 50 37 82 61 N/A N/A 99 73
300 12" 57 42 111 82 N/A N/A 132 97
350 14" 60 44 120 89 N/A N/A 225 166
400 16" 88 65 170 125 N/A N/A 210 155
450 18" 92 68 170 125 N/A N/A 220 162
500 20" 103 76 230 170 N/A N/A 200 148
600 24" 161 119 350 258 N/A N/A 280 207
Nominal size
PN 10 PN 16 PN 40 Class 150
Maximum allowable
torques
(continued)
Installation of add-on
module
The module must be mounted on the backside
of the MAG 8000 or MAG 8000 CT electronic.
Use the two 3 mm screws and washers to fix the
module to the MAG 8000 or MAG 8000 CT
electronic, with maximum torque 0.5 Nm.