5.4 Power Supply Ratings
Table 18: Power supply ratings
Parameter Description Conditions Min Typ Max Unit
Supply voltage Directly measured at reference point
TP BATT+ and TP GND, see chapter
3.2.2
Voltage must stay within the min/max
values, including voltage drop, ripple,
spikes.
3.2 3.8 4.5 V
Voltage drop during
transmit burst
Normal condition, power control level
for P
out max
400 mV
BATT+
Voltage ripple Normal condition, power control level
for P
out max
@ f<200kHz
@ f>200kHz
50
2
mV
mV
I
VDDLP
RTC Backup @ BATT+ = 0V 25 µA OFF State
supply current
POWER DOWN mode
1)
50 100 µA
SLEEP mode @ DRX = 9 TBD mA
SLEEP mode @ DRX = 5 TBD mA
SLEEP mode @ DRX = 2 TBD mA
I
BATT+
Average standby
supply current
2)
IDLE mode @ DRX = 2 TBD mA
1)
Measured after module INIT (switch ON the module and following switch OFF);
applied voltage on BATT+ (w/o INIT) show increased POWER DOWN supply current.
2)
Additional conditions:
SLEEP measurements started 3 minutes after switch ON the module
Averaging times: SLEEP mode - 3 minutes; IDLE mode - 1.5 minutes
Communication tester settings: no neighbor cells, no cell reselection
USB interface disabled